Comparison of Tricuspid Regurgitation Severity Between Cardiac Resynchronization Therapy Versus Right Ventricular Pacing in Patients With Chronic Obstructive Pulmonary Disease

James Livesay, Benjamin Fogelson, Hassan Tahir, Raj Baljepally

Abstract


Background: Right ventricular (RV) lead placement can worsen tricuspid regurgitation (TR). TR is known to be associated with lower survival irrespective of left ventricular ejection fraction (LVEF) or pulmonary hypertension (PH). Patients with chronic obstructive pulmonary disease (COPD) often have PH and pre-existent TR with higher morbidity and mortality from worsening TR. Prior studies are lacking to indicate if cardiac resynchronization therapy (CRT) may be more beneficial in lessening TR in COPD patients. Therefore, we sought to study if patients with COPD will have less TR with CRT versus non-CRT devices.

Methods: We performed a retrospective, single-center analysis on 154 COPD patients (mean age = 71.69 10.58, males = 54.14%) that required single-chamber (n = 27), dual-chamber (n = 90), or CRT (n = 37) devices. TR severity, LVEF and right ventricular systolic pressure (RVSP) were evaluated by two cardiologists in a blinded fashion. Analysis of variance (ANOVA) and Chi-square tests were applied for continuous and categorical variables respectively. The primary endpoint was a change in the severity of TR comparing pre-device versus post-device echocardiogram. Secondary endpoints included changes in LVEF and RVSP.

Results: COPD patients, who underwent a CRT device had a significantly lower incidence of worsening TR (16%) when compared to single- (37%) (P = 0.001) and dual-chamber devices (30%) (P = 0.02). The increase in RVSP was similar between the groups. There was an expected improvement in LVEF in the CRT group.

Conclusions: COPD patients receiving a CRT device were least likely to have worsening TR, compared to single- or dual-chamber devices. Since both COPD and progression in TR may result in poor outcomes, our study may suggest that an upfront strategy of CRT rather than a single- or dual-chamber device may be more beneficial in COPD patients, especially with pre-existent TR.




Cardiol Res. 2022;13(3):128-134
doi: https://doi.org/10.14740/cr1365

Keywords


Tricuspid regurgitation; Chronic obstructive pulmonary disease; Cardiovascular implantable electronic device; Cardiac resynchronization therapy; Right ventricular pacing

Full Text: HTML PDF
 

Browse  Journals  

 

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

 

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

 

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

 

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

 

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 
       
 

Cardiology Research, bimonthly, ISSN 1923-2829 (print), 1923-2837 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.

This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.cardiologyres.org   editorial contact: editor@cardiologyres.org
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.


Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.